Description
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops – Standard EN45555 – 85.2 %
ABB Site Meeting Group Waste To Landfill Target:
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
Sustainable Material Content in Packaging (wt. %):
Recycled Cardboard – 56.72 %
Recycled Paper – 0 %
Recycled Cardboard – 37.77 %
Recycled Paper – 0 %
Chemically Recycled Polymer – 3.71 %
Extended Product Lifetime:
Product Durability
End Of Life Disassembling Instructions:
Environmental Product Declaration – EPD:
Technical
Suitable for Isolation:
Yes
Dielectric Test Voltage:
2.5 kV
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
10 kA
Rated Service Short-Circuit Breaking Capacity (Ics):
6 kA
Power Supply Connection:
Arbitrary
Contact Position Indication:
Red ON / Green OFF
Energy Limiting Class:
3
Electrical Endurance:
20000 cycle
Mechanical Endurance:
20000 cycle
Number of Protected Poles:
1
Number of Poles:
1P+N
Number of Modular Spacings per DIN Rail:
1
Position of Neutral Terminals:
Right
Tightening Torque:
Bottom 2 N·m
Top 1.2 N·m
Screw Terminal Type:
Cage Terminal
Recommended Screw Driver:
Pozidriv 2
Accessories Available:
No
Connecting Capacity:
Conductor (Top) 10 flexible mm²
Conductor (Top) 16 rigid mm²
Conductor (Bottom) 16 flexible mm²
Conductor (Bottom) 25 rigid mm²
Wire Stripping Length:
Input Circuit 13 mm
Output Circuit 13 mm
Terminal Type:
Screw Terminals
Actuator Type:
Toggle
Electrical
Tripping Characteristic:
C
Rated Operational Voltage:
230 … 240 V AC
Rated Impulse Withstand Voltage (Uimp):
4 kV
Input Voltage Type:
AC
Rated Current (In):
32 A
Rated Short-Circuit Capacity:
10 kA
Rated Frequency (f):
50 / 60 Hz
Power Loss:
Total 4.06 W
Overvoltage Category:
III
Material Compliance
REACH Declaration:
Conflict Minerals Reporting Template (CMRT):
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer
Environmental
Ambient Air Temperature:
Storage -25…70 °C
Operation -25…55 °C
Degree of Protection:
Housing IP40
Terminals IP20
Pollution Degree:
2
Dimensions
Width in Number of Modular Spacings:
1
Product Net Width:
17.5 mm
Product Net Height:
110 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
0.182 kg
Built-In Depth (t2):
69 mm
Dimension Diagram:
Ordering
Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.196 kg
Installation
Instructions and Manuals:
Wiring Diagram:
Mounting Type:
DIN-Rail
Mounting Position:
Vertical/Horizontal
External Classifications and Standards
ETIM 9:
EC000905 – Earth leakage circuit breaker
ETIM 10:
EC000905 – Earth leakage circuit breaker
Object Classification Code:
F
Standards:
IEC 61009-1
IEC 61009-2-2