Description
The Green EBM EKEC6 Smart Wallbox delivers high-efficiency Mode 3 AC charging engineered for homes, workplaces, and commercial fleet deployments. Flexible in design, it supports both socket-type (Case B) and tethered cable (Case C) configurations across single-phase (AC 240V) and three-phase (AC 420V) electrical networks.
Key Features & Highlights:
Versatile Power Output: Available in 3.6 kW and 7.2 kW (Single-Phase) as well as 11 kW and 22 kW (Three-Phase) options.
Smart Energy Management: Equipped with Dynamic Load Balancing (DLB) and Modbus-RTU communication protocol support for intelligent power optimization.
User Control & Interface: Features an integrated LCD display, multi-color LED indicators, and secure RFID card authorization.
Advanced Electrical Safety: Includes RDC-DD DC 6mA residual direct current detection, over-temperature protection, and Class I shock protection.
Weatherproof & Flexible Mounting: Rated IP54 for dust and water resistance, suitable for wall, pole, or pedestal mounting in indoor and outdoor settings.
Universal Compatibility: Supports T1 (SAE J1772), T2 (IEC/EN 62196-2), and GB/T 20234.2-2015 connector standards.
Technical Specifications
| Technical Data | ||
| EV charging modes | Mode 3 Charging | |
| Power supply | 1P+N+PE | 3P+N+PE |
| Rated voltage | AC 240V±10% | AC 420V±10% |
| Rated power | 3.6kW, 7.2kW | 11kW, 22kW |
| Rated current | Max 16A, Max 32A | |
| Rated frequency | 50Hz | |
| Over voltage category (OVC) | OVC III | |
| Insulation resistance | R > 1 MΩ | |
| AC withstand voltage | 1430V | |
| Impulse dielectric withstand voltage (1.2 μs/50 μs)(uimp) | 4kV | |
| Protection against electric shock | Class I | |
| Electrical life (Contactor) | 100,000 | |
| Electrical life (Interface) | 100,000 | |
| Standby power consumption | < 8W | |
| Type of EV connection | Case B (Socket version) / Case C (Cable version) | |
| Universal interface | T1: SAE J1772; T2: IEC/EN 62196-2, GB/T: 20234.2-2015 | |
| Support protocol | Modbus-RTU | |
| Functional | DLB, LED, LCD, RFID | |
| Protection | RDC-DD DC 6mA; Over temperature protection | |
| Pollution degree | PD 3 | |
| Ip protection class | IP54 | |
| Altitude during operation (m) | < 2000m | |
| Altitude of test laboratory | < 50m | |
| Work humidity | 3%~95% | |
| Operation temperature | -25°C~+55°C | |
| Cooling | Natural air cooling | |
| Mounting method | Mounted on walls, poles or equivalent positions | |
| Normal environmental conditions | Indoor use; Outdoor use |